reasons for motor drawing high current

What is the cause of pulling high amps on one leg of the

Excessive resistance (drag) will cause motor to draw more amps (current flow) to operate. What causes high amps High voltage and low resistance would cause high amps.

Commmon Reasons for Contactor Failure

Some of the common reasons are excess current flowing through the contacts. High current can be either due to overload or due to short-circuit. High current can cause the contacts to melt. The electrodynamic forces during a short circuit can mechanically damage the contactor. Another cause of contact failure is overvoltage. Overvoltage causes

What is Cause of High Current in New Submersible Pump

May 18 2012 · However there is one problem. The current being drawn by the pump motor is 5.1 amperes and the FLA specification is 3.7 amperes. Here is what I believe to be the pertinent information MANUFACTURER SPECIFICATIONS Goulds Pump7GS05422C MotorM05422-50C211

When people talk about a device "drawing" current what do

begingroup If you are asking about motors rather than the term "draw" the resistance does not change under load but something called the back-EMF does. The back EMF of a freely spinning motor will cause the current to be at its minimum. The back-EMF disappears when the motor

Why Motors Fail Part 1 Franklin AID

Feb 15 2012 · Overloads protect motor windings against heat damage caused by high current. The job of the overload is simple-detect the condition and take the motor off-line. All Franklin Electric 60 Hz single-phase motors have overload protection built-in either in the motor itself or in the control box (see the May / June 2011 edition Franklin AID for

Troubleshooting GuideAC Motors Groschopp

Load too high. Verify that the load is not jammed. If the motor is a replacement verify that the rating is the same as old motor. If the previous motor was a special design a stock motor may not be able to duplicate the performance. Remove the load from the motor and inspect the amp draw of the motor

I have 3 phase motor that trips over phase unbalance

Measure the unbalanced current of all three phases with scale draw three vectors line 120degree apart from same point representing three vector current taking length scale to current as all

Troubleshooting With Compressor Amperage

Mar 31 2005 · The published RLA value does not change as the motor load changes. Different articles and even some instructors have stated that high evaporator loads will cause high amp draws. This can easily be misconstrued. While a higher load will increase the amp draw it does not equate to improper amps even if the compressor trips on its overload.

What causes a motor to draw higher than normal amps AMP

If not that narrows it down to imbalance power supply or high resistance connection or remotely some kind of problem with motor (swap leads at that point and see if the high current follows the motor lead to narrow it down). Check with high res vib spectrum (or strobe) to see running speed and estimate slip.

Electric motor starting run capacitor troubleshooting FAQs

Electric motor starting run capacitor troubleshooting FAQs Questions Answers about Electric Motor Start-Boost or Run Capacitors Capacitors are electric devices that get an electric motor running at start-up or that help keep a motor running once it has started. If the capacitor has failed the symptom is that the motor won t start. You may hear it humming or observe that it s getting hot.

Unbalanced Current EC M

Next de-energize the motor and connect A to 3 B to 1 and C to 2 operate the motor and again measure the current in each line. If the high current and low current readings follow the same line leads the supply is the cause of the problem. If the high and low readings follow the motor leads the motor

Pump Overloading and its causesEnggCyclopedia

Causes of Centrifugal pump overloading. Pump overloading may be caused by the motor drawing a high current due to the following reasons. Speed too high Process liquid of higher viscosity. Oversized impeller installed Total head of system either higher or lower than

Troubleshooting Electrical Motor and Compressor Problems

Jun 19 2006 · Low line voltage causes the motor to draw more current than normal and may result in overheating and premature failure. Line voltage that is too high will cause excessive inrush current at motor start again leading to premature failure. 2. Check line voltage at the motor

Understanding Motor Starting (Inrush) Currents NEC

High resistance is often encountered when starting a motor from a static (idle) position and excessive current draw is necessary to begin rotation of the motor shaft. Often during the initial half-cycle of electrical current flow experienced at motor startup (Note A half-cycle in a 60 Hz electrical system equates to 1/120 of a second

The Highs and Lows of Motor Voltage EC M

An assumption people often make is that since low voltage increases the amperage draw on motors then high voltage must reduce the amperage draw and heating of the motor. This is not the case. High voltage on a motor tends to push the magnetic portion of the motor into saturation. This causes the motor to draw excessive current in an effort to

Why motor initial starting current is high

In case of motor current is given by i=(v-e)/r.here v=suplly voltage e=back emf and r=resistace.during starting back emf is zero.then i=v/r.generally motor resistance is low.so during starting motor draws high current which is normally 5 to 6 times its normal operating current.

HOW TO MEASURE BLOWER MOTOR AMP DRAW Contracting

Record the reading and compare it to the FLA listed on the motor. Check the amp draw against the manufacturer s fan performance data to verify the airflow that the fan is producing. A rule of thumb is that on high speed most motors will draw 70-100 of the FLA if it is moving the required 400 CFM per ton on residential systems.

Blower Motor Drawing To much amp shorting out coil on

Jul 21 2015 · How to service the 80 AFUE gas furnace. Check amp draw and bearings of the motors. Part 7Duration 6 36. grayfurnaceman 10 081 views

Why Pool Pumps Overheat — And What You Can Do To Stop It

Since current and resistance are inversely proportional that means the motor will draw more current. Power in an electrical system is equal to the squared current multiplied by the resistance. This means as the current

Why do motors draw higher amps on higher loads General

Oct 23 2009 · If you put a DC voltage on a motor it would draw very high amps because it would effectivly become a short circuit because there are no magnetic fields being created to limit the current.

powerWhy do car starter motors draw so much current

The motor doesn t draw high current because it "needs" to develop high torque. Rather a stationary motor is just a coil of low-resistance wire. It draws a high current because of Ohm s law and that high current causes a strong magnetic field which in turn generates high

Imbalance in current drawn by 3-phase induction motor.

I have IM which is 55kw with full load current rating of 77.78 amperes 415v 3-phase. Whenever I run the motor with some load there is imbalance in current drawn by motor upto 2 amperes when the

What s causing your high motor current

Feb 23 2018 · The most common causes of high no-load current after a motor is rewound are incorrect winding data and stator core damage. Incorrect winding data that increases the magnetic flux levels as compared with design levels will result in increased no-load current.

Why the starting current of induction motor is very high

Induction motor resembles as a poly phase transformerthe reason behind high starting current Thus Induction motor is similar to a transformer where the primary is the stator and secondary is the rotor.Now we know the concept of transformer that the primary current and secondary current is inter-related.

How Current Shunts Work Hackaday

Feb 08 2018 · A high resistance will limit the current that can pass through the circuit and also waste power as heat. For these reasons the current shunt resistance should be as low as possible.

Imbalance in current drawn by 3-phase induction motor.

I have IM which is 55kw with full load current rating of 77.78 amperes 415v 3-phase. Whenever I run the motor with some load there is imbalance in current drawn by motor upto 2 amperes when the

Polyphase AC Induction Motor TROUBLESHOOTING GUIDE

overload capacity of motor ie 50 HP x 1.15 = 57.5 HP. Current draw at service factor load would approximate the amps listed times 1.15. Serial Number Unique number identifies when the motor was manufactured. NEMA Code Indicates the motor s starting KVA code letter which can be used to approximate starting or locked rotor current draw

Definition of Overcurrent in an Electrical Circuit

Short circuits occur when a "hot" wire (an ungrounded wire usually black or red) touches another hot wire or comes in contact with a neutral wire (a grounded wire usually white).Shorts can also happen if there is a break in a wire in the circuit. The short circuit path has lower resistance the normal path of the circuit allowing a great deal of current

Common Causes for Electric Motor FailureMotor Failure

Overheating also occurs when an electric motor is forced to operate in a high temperature environment. This causes the rate at which heat can be conducted to reduce at an alarming rate. The area where electric motors are operating must have a proper cooling system and a ventilation system should be there in case the cooling system stops working.

Common Causes for Electric Motor FailureMotor Failure

Most of the electric motor failures occur at the start up. Most of them are caused by the over-heating of motor. There are also other factors which greatly affect the performance of electric motors such as low resistance dirt moisture over-current and vibrations. Electric motors should be installed very carefully and should be looked after at regular intervals.

Unbalanced Current EC M

Next de-energize the motor and connect A to 3 B to 1 and C to 2 operate the motor and again measure the current in each line. If the high current and low current readings follow the same line leads the supply is the cause of the problem. If the high and low readings follow the motor leads the motor

Solutions

Fixed belt conveyors in mineral processing plant

The belt conveyor is a kind of friction driven equipment which transports materials in a continuous way. It is mainly composed of frame, conveyor belt, idler, pulley, tensioning device...

Simple mobile belt conveyor in handling solution

Universal wheels are installed at the bottom of the mobile conveyor, which can be moved at will according to the stacking position of materials...

mobile design radial belt conveyor solution

The radial telescopic conveyor is one of the most cost efficient and effective way of stockpiling material . The reduction of segregation, degradation...

Heavy mobile belt conveyor for barge loading

The mobile belt conveyor with wheels could be applied for all kinds of block and granular material.It composed of conveying belt unit, arm stretch unit, hydraulic pressure control system...

TOP